Qualitative characteristic use in stability study inspection plan with inspection point

$
0
0

Dear Gurus,

 

I am new QM module, I am not able to create inspection plan for stability study material which have qualitative characteristic.

please detail me how to create sample procedure for qualitative characteristic which can be used with inspection point 200 at header level.

 

I am using T.code CWBQM to create plan, getting below error while defining qualitative characteristic.

 

Note - sample procedure - sampling  type = 100 (fixed), valuation mode - 400 (valuation acc. to char attb.), selected - sample management, control chart - 121

 

MIC -selected control indicator - Sampling procedure, summ. recording, req. char, fixed scope, long term inspection, no doc., print

 

The sampling procedure is only suitable for SPC characteristics

Message no. QD247

Diagnosis

You can maintain a control chart in the sampling procedure BETA_ST. It can, therefore, only be used for characteristics which are marked as SPC characteristics in the control indicators.

System Response

You cannot select this sampling procedure.

Procedure

Choose a different sampling procedure or set the indicator for the SPC characteristic in the characteristic

 

Please understand urgency as we are near to go live.