Re: System Count is not coming in reprots

$
0
0

Yes Mr.Jurgen Sir. I am never come that area but have a idea so that I had expressed here a little bit knowingly.

Here for Phy. Inv for WM,

 

Phy. Inv for WM

 

 

Create Inventory doc LI01N

Enter Coun  LI11N,

Adjut Difference WM LI20

Clear Difference in IM with LI21

 

As you stated earlier message in your thread below lines, from that I got your point fully.

 

The main difference between physical inventory in IM and WM is that in IM you count by material within a storage location, while in WM you are supposed to count by bin (usually any material in a bin).

 

LI01N in WM  is the equivalent to  MI01  in inventory managment

LI11N in WM  is the equivalent to  MI04  in inventory managment

posting difference in WM is done thru in LI20 and LI21 while it is done with MI07 in inventory managment.

 

Thank you always Mr. Jurgen Sir!

 

Regards,

Vivek